Service | Clean air and compatible, non-combustible gases |
Accuracy | 3% FS Process gas: 32 to 122 F |
Response Time | Flow: 15 s to 95% of final value (output filter set to min) |
Temperature Limits | Process: -40 to 212 F (-40 to 100 C) Ambient: 32 to 140 F (0 to 60 C) |
Pressure Limit | 100 psi (689 bar) maximum |
Humidity Limit | Non-Condensing |
Power Requirments | 12 to 35 VDC, 10 to 16 VAC |
Output Filter | Selectable 05-15 s |
Loop Resistance | 600 Ω max |
Current Consumption | 300 mA max |
Outputs | 4-20 mA |
Electrical Connections | Screw terminal |
Mounting Orientation | Unit not position sensitive Probe must be aligned with airflow |
Cable Length | 6' (182 m) |
Display | 4-1/2 digit 1/2" red LED |
Resolution | 1 FPM, 001 MPS (10 FPM @ 10,000 and 15,000 FPM ranges) |
Approvals | RoHS |
Downloads | |