Service | Air and compatible, non-combustible gases |
Accuracy | 5% FS process gas: 32 to 122 F |
Response Time | Flow: 15 s to 95% of final value (output filter set to min) |
Temperature Limits | Process: -40 to 176 F (-40 to 80 C) Ambient: 32 to 140 F (0 to 60 C) |
Humidity Limit | Non-condensing |
Power Requirments | 12 to 35 VDC, 10 to 16 VAC |
Output Filter | Selectable 05-15 s |
Loop Resistance | 600 Ω max |
Current Consumption | 300 mA max* |
Outputs | 4-20 mA |
Electrical Connections | Screw terminal |
Mounting Orientation | Unit not position sensitive |
Approvals | RoHS |
Downloads | |